VIFB8 – 02
24 V supply (electronic
components and/or
inputs)
Fig. 4/20: Pin assignment of operation voltage connection
4-34
4. Installation
Applying the 24V operating voltage
CAUTION
Please observe the polarity when the opera-
ting voltage is applied. Connect the earthing to
pin 4, PE.
The following diagram shows the pin assignment
of the operating voltage connection. A suitable
24V DC supply should be connected via the
mains connection socket (see Chapter 3, Techni-
cal specifications). Please see also the example
of connection in Fig. 4/21.
2
1
3
4
The operating voltage supply to the electronic
components and for inputs is fused at the valve
terminal/valve sensor terminal (4A, slow blow-
ing).
PLEASE NOTE
The operating voltage supply to the outputs is
not fused.
24 V supply
(outputs)
0 V
PE
(Protective Earth)
9706