Preparing The Connection Block - Festo VIFB-02 Series Manual

Valve terminal/valve sensor terminal with field bus connection
Hide thumbs Also See for VIFB-02 Series:
Table of Contents

Advertisement

VIFB8 – 02
5/3
Connections for
common lines
1
(adhesive foil)
3/5
Connection of common lines
Unilateral
Bilateral
Fig. 4/3: Connections on the connection block
9706
4. Installation

Preparing the connection block

Connections for common lines are provided on
both sides of the connection block. The common
lines can therefore be fitted either on the right or
the left, depending on individual requirements.
To increase the air flow we recommend that the
lines for compressed air supply and ventilation
be connected on both sides in the following
cases:
When the valve terminal/valve sensor termi-
nal has more than 10 valves (rated supply
pressure 6 bar)
With large-volume actuators
The connections should be made in accordance
with the table below:
Procedure
Remove all adhesive fiols;
remove all blind plugs and fit on one side
Remove all foils and blind plugs
Connections for
common lines
(blind plugs)
4-9