Sign In
Upload
Manuals
Brands
Eaton Manuals
UPS
9395 UPS and Plus 1 UPS 650825 kVA
Eaton 9395 UPS and Plus 1 UPS 650825 kVA Manuals
Manuals and User Guides for Eaton 9395 UPS and Plus 1 UPS 650825 kVA. We have
1
Eaton 9395 UPS and Plus 1 UPS 650825 kVA manual available for free PDF download: Installation And Operation Manual
Eaton 9395 UPS and Plus 1 UPS 650825 kVA Installation And Operation Manual (192 pages)
Powerware
Brand:
Eaton
| Category:
UPS
| Size: 2 MB
Table of Contents
Save These Instructions
2
Important Safety Instructions
2
Table of Contents
3
1 Introduction
11
UPS Standard Features
11
Installation Features
11
Warranty
11
Control Panel
12
Customer Interface
12
Figure 1-1. Powerware 9395 UPS (650-825 Kva)
12
Advanced Battery Management
13
Power Management Software
13
Figure 1-2. Powerware 9395 UPS (650-825 Kva) with the Field Installed UPM
13
Options and Accessories
14
Field Installed UPM
14
Inherent Redundancy
14
Sync Control
14
Monitoring and Communication
14
Single−Feed Kit
15
Separate Rectifier Input
15
Distributed Bypass System
15
Input Output Module Configuration
15
Battery System
15
Basic System Configurations
16
Using this Manual
16
Conventions Used in this Manual
16
Symbols, Controls, and Indicators
17
For more Information
17
Getting Help
18
2 Safety Warnings
19
Section I - Installation
21
3 UPS Installation Plan and Unpacking
23
Creating an Installation Plan
23
Preparing the Site
23
Environmental and Installation Considerations
23
Figure 3-1. UPS Cabinet Dimensions (Front View)
25
Figure 3-2. UPS Cabinet Dimensions (Right Side View)
25
Figure 3-3. ISBM Section Dimensions (Front View)
26
Figure 3-4. UPM Section Dimensions (Front View)
26
Figure 3-5. ISBM Section Dimensions (Top View)
27
Figure 3-6. ISBM Section Dimensions (Bottom View)
27
Figure 3-7. UPM Section Dimensions (Top View)
27
Figure 3-8. ISBM Section Center of Gravity
28
Figure 3-9. UPM Section Center of Gravity
28
Figure 3-10. Remote EPO Switch Dimensions
29
UPS System Power Wiring Preparation
30
UPS System Interface Wiring Preparation
41
Distributed Bypass Power Wiring Preparation
42
Inspecting and Unpacking the UPS Cabinets
43
Figure 3-11. UPS Cabinet as Shipped on Pallet (ISBM Section)
44
Figure 3-12. UPS Cabinet as Shipped on Pallet (UPM Section)
45
Unloading the UPS Sections from the Pallet
47
Preliminary Installation Information
47
4 UPS System Installation
47
Figure 4-1. Removing the ISBM Section Left Side Shipping Bracket
48
Figure 4-2. Removing the ISBM Section Right Side Shipping Bracket
49
Figure 4-3. Removing the UPM Section Left Side Shipping Bracket
50
Figure 4-4. Removing the UPM Section Right Side Shipping Bracket
51
Mechanically Joining the Sections
51
Figure 4-5. Section Joining
52
Figure 4-6. ISBM and UPM Sections Joined
53
Electrically Connecting the Sections
54
Figure 4-7. ISBM Section to UPM Section Joining Brackets
54
Figure 4-8. ISBM Section Intercabinet Power Terminal Locations - Common Rectifier Feed
57
Figure 4-9. ISBM Section Input Power Terminal Detail - Common Rectifier Feed
58
Figure 4-10. ISBM Section Intercabinet Power Terminal Locations - Separate Rectifier Feed
59
Figure 4-11. ISBM Section Input Power Terminal Detail - Separate Rectifier Feed
60
Figure 4-12. ISBM Section Battery Input Power Terminal Detail
61
Figure 4-13. ISBM Section Output Power Terminal Detail
61
Figure 4-14. UPS Intercabinet Interface Harness Locations
62
Figure 4-15. Pl1 Interface Board Location
63
Figure 4-16. J39 Location on Pl1 Interface Board
63
Battery System Installation
64
Distributed Bypass Tie Cabinet Installation
64
Field Installed UPM Installation
64
Installing UPS External and Battery Power Wiring
64
External Power Wiring Installation
64
Figure 4-17. ISBM and UPM Section Debris Shields
65
Figure 4-18. ISBM Section Conduit and Wire Entry Locations
66
Figure 4-19. Distributed Bypass Wire Length
68
Figure 4-20. ISBM Section Power Terminal Locations - Common Rectifier Feed
69
Figure 4-21. ISBM Section Power Terminal Detail AA - Common Rectifier Feed
70
Figure 4-22. ISBM Section Power Terminal Locations - Separate Rectifier Feed
71
Figure 4-23. ISBM Section Power Terminal Detail AA - Separate Rectifier Feed
72
Figure 4-24. UPM Rectifier Input Power Terminal Block Detail
73
Battery Power Wiring
74
Figure 4-25. ISBM Section Power Terminal Detail BB - Common Battery
75
Figure 4-26. ISBM Section Power Terminal Detail CC - Separate Battery
76
TB1, TB2, and TB3 Connections (Other than TB1 Battery Interface Connections)
77
Installing Interface Connections
77
Figure 4-27. ISBM Section Interface Terminal Locations
78
Figure 4-28. Interface Terminal Detail
80
Figure 4-29. Typical Alarm Relay Connection
80
Figure 4-30. Terminal Blocks TB1, TB2, and TB3 Connector Assignments
81
TB1 Battery Interface Connections
82
Figure 4-31. Typical Battery Interface Connection - Common Battery System
83
Figure 4-32. Typical Battery Interface Connection - Separate Battery System
83
Figure 4-33. X−Slot Communication Bays
84
X−Slot Connections
84
Figure 4-34. REPO Switch
85
Installing a REPO Switch
85
Figure 4-35. Normally−Open REPO Switch Wiring
86
Figure 4-36. Normally-Closed REPO Switch Wiring
87
Completing the Installation Checklist
88
Initial Startup
88
Figure 4-37. Normally-Closed and Normally-Open REPO Switch Wiring
88
Installation Checklist
89
Distributed Bypass Installation Checklist
90
Installing Options, Accessories, and Distributed Bypass Control Wiring
88
Installing an Optional Powerware Hot Sync CAN Bridge Card
93
5 Installing Options and Accessories
93
Figure 5-1. Powerware Hot Sync CAN Bridge Card
93
Figure 5-2. Powerware Hot Sync CAN Bridge Card Connections
95
Installing Distributed Bypass Control Wiring
96
Figure 5-3. Distributed Bypass System Can and Pull−Chain Simplified Interface Wiring
97
Figure 5-4. Distributed Bypass System UPS CAN Wiring Without Mobs
97
Figure 5-5. Distributed Bypass Pull−Chain Wiring Without Mobs
98
Figure 5-6. Distributed Bypass Pull−Chain Wiring with Mobs
99
Installing an Optional Remote Monitor Panel II
101
Figure 5-7. Remote Monitor Panel II and Relay Interface Module II Terminal Locations
102
Figure 5-8. Remote Monitor Panel II, Relay Interface Module II, or Supervisory Contact Module II Wiring
102
Installing an Optional Relay Interface Module II
103
Figure 5-9. J1, J2, J3, and J4 15−Pin D−Sub Connectors
104
Figure 5-10. Supervisory Contact Module II Terminal Location
105
Installing an Optional Supervisory Contact Module II
105
Figure 5-11. Supervisory Contact Module II TB2
106
Accessory Mounting Dimensions
107
Figure 5-12. Remote Monitor Panel II Dimensions
107
Figure 5-13. Relay Interface Module II Dimensions
108
Figure 5-14. Supervisory Contact Module II Dimensions
109
Operation
111
6 Understanding UPS Operation
113
UPS System Overview
113
Figure 6-1. Main Elements of the UPS System
113
Normal Mode
114
Single UPS
114
Modes
114
Figure 6-2. Path of Current through the UPS in Normal Mode
115
Bypass Mode
116
Figure 6-3. Path of Current through the UPS in Bypass Mode
116
Battery Mode
117
Figure 6-4. Path of Current through the UPS in Battery Mode
118
Single UPS Unit System Oneline Configurations
119
Figure 6-5. UPS System – Common Rectifier Feed, Common Battery, Dual-Feed Configuration
120
Figure 6-6. UPS System – Common Rectifier Feed, Separate Battery, Dual-Feed Configuration
121
Figure 6-7. Plus 1 UPS System – Common Rectifier Feed, Common Battery, Dual-Feed Configuration
122
Figure 6-8. Plus 1 UPS System – Common Rectifier Feed, Separate Battery, Dual-Feed Configuration
123
Figure 6-9. UPS System – Common Rectifier Feed, Common Battery, IOM Configuration
124
Figure 6-10. UPS System – Common Rectifier Feed, Separate Battery, IOM Configuration
125
Figure 6-11. Plus 1 UPS System – Common Rectifier Feed, Common Battery, IOM Configuration
126
Figure 6-12. Plus 1 UPS System – Common Rectifier Feed, Separate Battery, IOM Configuration
127
Figure 6-13. UPS System – Separate Rectifier Feed, Separate Battery, Dual-Feed Configuration
128
Figure 6-14. Plus 1 UPS System – Separate Rectifier Feed, Separate Battery, Dual-Feed Configuration
129
Figure 6-15. UPS System – Separate Rectifier Feed, Separate Battery, IOM Configuration
130
Figure 6-16. Plus 1 UPS System – Separate Rectifier Feed, Separate Battery, IOM Configuration
131
Figure 6-17. Simplified Dual−Feed UPS with Maintenance Bypass Panel
132
Multiple UPS Distributed Bypass System
133
Multiple UPS Parallel System Modes
133
Figure 6-18. Path of Current through the Upss in Normal Mode – Distributed Bypass
134
Normal Mode – Distributed Bypass
134
Figure 6-19. Path of Current through the Upss in Bypass Mode – Distributed Bypass
135
Bypass Mode – Distributed Bypass
135
Battery Mode – Distributed Bypass
136
Figure 6-20. Path of Current through the Upss in Battery Mode – Distributed Bypass
137
Multiple UPS Distributed Bypass System Oneline Configurations
138
Figure 6-21. Typical Distributed Bypass System (1+1 and 2+0 Configurations)
139
Figure 6-22. Typical Distributed Bypass System (2+1 and 3+0 Configurations)
140
Figure 6-23. Typical Distributed Bypass System (3+1 and 4+0 Configurations)
141
Figure 7-1. UPS Controls and Indicators – ISBM Section Shown
143
7 UPS Operating Instructions
143
UPS Controls and Indicators
143
Control Panel
144
Using the Control Panel
144
Circuit Breaker
144
Figure 7-2. UPS Control Panel
144
Status Indicators
145
System Events
145
Using the LCD and Pushbuttons
146
Figure 7-3. Parts of the LCD
146
Using the Menu
147
MIMIC Screen
147
Figure 7-4. Main Menu and MIMIC Screen (Normal Mode)
147
Display Menu Operation
148
System Status Screen and Controls
150
Figure 7-5. Typical System Status Screen
150
Load off Screen
152
Figure 7-6. Load off Screen
152
Starting the UPS in Normal Mode
153
Single UPS Operation
153
Starting the UPS in Bypass Mode
154
Starting the Upms
154
Transfer from Normal to Bypass Mode
156
Transfer from Bypass to Normal Mode
156
Transfer from Normal to Bypass Mode and Shut down UPS
157
Single UPM Shutdown
157
UPS and Critical Load Shutdown
158
Charger Control
158
Using the UPS LOAD off Pushbutton or Command
159
Using the Remote Emergency Power−Off Switch
160
Figure 7-7. REPO Operation
161
Starting the Distributed Bypass System in Normal Mode
162
Multiple UPS Distributed Bypass Operation
162
Starting the Distributed Bypass System in Bypass Mode
163
Starting the Upss Upms
163
Transfer from Bypass to Normal Mode
165
Transfer from Normal to Bypass Mode
165
Transfer from Normal to Bypass Mode and Shut down All Upss
166
Single UPM Shutdown
166
UPS and Critical Load Shutdown
167
Charger Control
167
Using the UPS LOAD off Pushbutton or Command
168
Using the Remote Emergency Power−Off Switch
169
8 Communication
171
X−Slot Cards
171
Installing Enotify Service
172
Enotify Service Features
172
Enotify Service
172
Figure 8-1. Optional X−Slot Cards
172
Powerware Lansafe Power Management Software
173
Remote Notification
173
Display UPS Control Panel
174
Terminal Mode
174
Event History Log
175
Figure 8-2. Sample Event History Log
176
General Purpose Relay Contact
177
Building Alarm Monitoring
177
Remote Monitor Panel II
177
Figure 8-3. Remote Monitor Panel II Front Panel
177
Relay Interface Module II
179
Figure 8-4. Relay Interface Module II Customer Interface Connectors J1 through J4
179
Supervisory Contact Module II
180
Figure 8-5. Supervisory Contact Module II Enclosure
180
Important Safety Instructions
181
9 UPS Maintenance
181
Performing Preventive Maintenance
182
MONTHLY Maintenance
182
DAILY Maintenance
182
Figure 9-1. ISBM Section Air Filter Locations
183
Figure 9-2. UPM Section Air Filter Locations
184
PERIODIC Maintenance
185
Installing Batteries
185
BATTERY Maintenance
185
ANNUAL Maintenance
185
Figure 9-3. FI−UPM Air Filter Location
185
Recycling the Used Battery or UPS
186
Maintenance Training
186
10 Product Specifications
187
Model Numbers
187
UPS Input
187
UPS Environmental
188
UPS Output
188
Warranty
189
Advertisement
Advertisement
Related Products
Eaton Powerware Plus 1
Eaton POWERWARE Plus 18
Eaton Pulsar Series 1150
Eaton Ellipse PRO 1600 FR
Eaton Ellipse PRO 1200 DIN
Eaton Ellipse PRO 650 FR
Eaton PW9340-130I-SCR
Eaton PW9340-130I -NHS
Eaton PW9340-100I-NHS
Eaton PW9340-100I-SCR
Eaton Categories
UPS
Circuit breakers
Switch
Industrial Equipment
Industrial Electrical
More Eaton Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL