Error message Description
E
8
Error
Table data
E
1 0
Error
Seam pattern
number
E
3 0
Error
Upper needle
bar position
E
4 0
Error
Needle field
area
E
4 2
Error
Enlargement
E
4 5
Error
Seam pattern
data
E
5 0
Pause
E
3
0 2
Error
Machine head
60
6.
Use the +/- Program keys to select the next stitch.
7.
Repeat steps 3 to 5 for all further stitches.
8.
Press the Ready key to save the edited seam pattern.
9.
Press the Reset key.
 The key LED goes out.
10. Press the USB key.
 The key LED goes out.

7.20 Error messages

If an error occurs, the Error symbol LED illuminates.
Possible cause
Table data could not be read • Save the table data
The selected seam pattern is
not stored in ROM or has
been disabled. Seam pattern
"0"
Needle bar is not in the
upper position
Needle field area exceeded
Sewing length is more than
10 mm
Seam pattern data could not
be accepted
Reset key pressed while
sewing.
Sewing automat stopped.
Machine head is tilted over.
Settings via software (sewing automat)
Remedy
anew.
• Press the Reset key to
confirm the seam pat-
tern number.
• Check the connections.
• Rotate the needle bar to
the top dead center.
• Press the Reset key.
• Check the X/Y scaling.
• Press the Reset key.
• Check the seam pattern
and the X/Y scaling.
• Press the Reset key.
• Check the ROM.
• Press the Reset key.
• Trigger the thread cutter.
• Start the sewing process
anew.
• Tilt the machine head
back into place.