Loading The Main Program - DURKOPP ADLER 550-532 Instruction Manual

Table of Contents

Advertisement

64

7.21.1 Loading the main program

Fig. 24: Loading the main program
(1) - Main switch
1.
Switch on the controller using the main switch (1).
2.
Plug the USB key into the USB port (2) of the controller.
3.
Press the USB key and wait approx. 3 seconds.
4.
Press the Memory key.
5.
Use the +/- Function keys to set a value of 5 in the Function
display.
6.
Press the Select key.
 The download into the controller starts.
Important
The download is finished when no more values are shown on the
Function display. Next, wait for at least 25 seconds as the con-
troller will otherwise be destroyed!
7.
Switch off the controller.
8.
Pull out the USB key.
Settings via software (sewing automat)
(2) - USB port
Instruction manual 550-532 - 00.0 - 07/2015