50

7.10 Pausing sewing

1.
Press the Reset key or press the pedal backwards.
 Sewing process paused, display shows error message E-50.
2.
Press the Reset key or press the pedal forwards to continue
sewing.

7.11 Disabling standard seam patterns

Standard seam patterns can be disabled so that they are no longer
displayed.
Prerequisite:
• Machine is in programming mode, Ready key LED is off.
1.
Press the Memory key and key P1 at the same time.
 The Program display shows the seam pattern number, the
Function shows 0 or 1:
0 = Seam pattern is displayed.
1 = Seam pattern is disabled.
2.
Press the +/- Function keys to select a different seam pattern.
3.
Press the Ready key to confirm the seam pattern.
4.
Press the +/- Function keys to select between 0 and 1.
5.
Press the Ready key to confirm the value.
6.
Press the Memory key.
Settings via software (sewing automat)
Instruction manual 550-532 - 00.0 - 07/2015