Changing The Needle - DURKOPP ADLER 550-532 Instruction Manual

Table of Contents

Advertisement

Operation of the sewing automat
Instruction manual 550-532 - 00.0 - 07/2015

5.8 Changing the needle

CAUTION
Risk of injury from the point of the needle and
moving parts
Only change the needle with the sewing automat
switched off.
Fig. 8: Changing the needle
(1) - Groove
(2) - Screw
1.
Loosen the screw (2) and remove the needle.
2.
Insert the new needle into the hole in the needle bar (3) as
far as it will go, taking care to ensure that the groove in the
needle (1) faces the hook tip.
3.
Tighten the screw (2).
4.
Always adjust the clearance between the hook and the needle
after changing to a different needle thickness (see  Service
Instructions).
Otherwise the following errors can occur:
• Changing to a thinner needle:
Missing stitches, thread damage
• Changing to a thicker needle: Damage to the hook tip,
damage to the needle
(3) - Needle bar
31

Advertisement

Table of Contents
loading

Table of Contents