Error
Meaning
1000
Sewing motor fault
1001
Sewing motor fault
1002
Sewing motor
insulation error
1004
Sewing motor fault
1005
Sewing motor current
feed fault
162

10.2.2 Error messages

If an error occurs, the
followed by a 4-digit number combination.
Possible cause
• Encoder plug (Sub-D, 9-pin)
not connected or defective
• Encoder defective
• Sewing motor plug not
connected or defective
• Incorrect direction of
rotation
• Sewing motor blocked
• Encoder cable not
connected or defective
• Encoder defective
symbol appears on the display,
Remedial action
• Check the connection of the
encoder cable and replace, if
necessary
• Check the connection of the
sewing motor cable
• Test sewing motor phases
(R = 2.8 Ω, high impedance
to PE)
• Replace the encoder
• Replace the sewing motor
• Replace the control
• Check motor phase and PE
for low-impedance
connection
• Replace the encoder
• Replace the sewing motor
• Replace the encoder
• Check plug assignment and
change, if necessary
• Check wiring in machine
distributor and change it, if
necessary
• Test motor phases and
check for correct value
• Remove the blockage
• Check the encoder cable
and replace, if necessary
• Replace the sewing motor