82

10.3 Servicing the pneumatic system

10.3.1 Setting operating pressure

NOTICE
Machine damage possible due to incorrect pressure.
Incorrect pressure can result in damage to the machine.
Check the pressure every day.
Have the pressure reset by qualified specialists if it deviates
from the standard value.
Fig. 37: Checking pneumatic system
(1) - Pressure gage
Proper setting
The operating pressure of the machine is 6 bar.
Checking the pressure
1.
Check the pressure on the pressure gage (1) every day.
Important: The pressure must never deviate from the standard
value by more than 1 bar.
Setting the pressure
1.
Pull the pressure controller (2) up.
2.
Turn the pressure controller until the pressure gage (1) indi-
cates 6 bar.
(2) - Pressure controller
Instruction manual 550-532 - 00.0 - 07/2015