Settings via software (sewing automat)
Instruction manual 550-532 - 00.0 - 07/2015

7.18 Resetting parameters to factory defaults

Prerequisite:
• Machine is in programming mode, Ready key LED is off.
1.
Press and hold the Memory key for 6 s.
 The key LED illuminates.
2.
Use the +/- Program keys to set parameter number U098.
3.
Press the Ready key.
4.
Use the +/- Function keys to enter a function value of 1.
5.
Press the Select key.
 The controller beeps once. If the controller beeps three
times then the reset was not successful.
6.
Set parameter U085.
Setting parameter U085
Prerequisite:
• Machine is in programming mode, Ready key LED is off.
1.
Press and hold the Memory key for 6 s.
 The key LED illuminates.
2.
Use the +/- Program keys to set parameter number U085.
3.
Press the Ready key.
4.
Use the +/- Function keys to enter a function value of 1.
 Press the Select key.