Optical "Line Port" Link Margin; On-Site Multiservice Node Final Test: Point-To-Point Measures - Alcatel-Lucent 1850 TSS-320 Turn-Up And Commissioning Manual

Transport service switch
Hide thumbs Also See for 1850 TSS-320:
Table of Contents

Advertisement

1850 TSS-320 Test Report Sheet Modules
............................................................................................................................................................................................................................................................
Table 5-8 On-Site Multiservice Node Final Test: Point-to-Point Measures
SITE 1
SITE 2
EQUIPMENT TYPE
EQUIPMENT RELEASE
Measure
Rx optical "line port"
power check
Rx optical "line port"
power check
Rx optical "line port"
power check
Rx optical "line port"
power check
Optical "line port" link
margin
Optical "line port" link
margin
Optical "line port" link
margin
Optical "line port" link
margin
E O W check
Point to point error monitoring check
............................................................................................................................................................................................................................................................
PN 8DG08136CAAA
Issue 1 March 2008

ON-SITE MULTISERVICE NODE FINAL TEST: POINT-TO-POINT MEASURES

PORT N°
PORT N°
PORT N°
PORT N°
PORT N°
PORT N°
PORT N°
PORT N°
Expected value and
tolderance
TYPE
Expected value = Remote PTx –
Theoretical line attenuation
based on customer data
TYPE
Expected value = Remote PTx –
Theoretical line attenuation
based on customer data
TYPE
Expected value = Remote PTx –
Theoretical line attenuation
based on customer data
TYPE
Expected value = Remote PTx –
Theoretical line attenuation
based on customer data
TYPE
Margin level must be min.
4 dB better than the values
reported in
"SFP and XFP
modules optical characteristics"
(p. 4-16)
TYPE
Margin level must be min.
4 dB better than the values
reported in
"SFP and XFP
modules optical characteristics"
(p. 4-16)
TYPE
Margin level must be min.
4 dB better than the values
reported in
"SFP and XFP
modules optical characteristics"
(p. 4-16)
TYPE
Margin level must be min.
4 dB better than the values
reported in
"SFP and XFP
modules optical characteristics"
(p. 4-16)
0 Errors
Equipment acceptance sheet
Measured
value
Unit
dBm
dBm
dBm
dBm
dBm
dBm
dBm
dBm
errors
5 - 9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents