Tests and Measurements
............................................................................................................................................................................................................................................................
– Select the remote port again, open the pop-up menu and select "Ethernet Port
Connect the instrument and check that the alarms (LOS and TSF) disappear.
•
– The alarm signalling is also displayed in the CT main window, by a red circle on
10 GbE Transport on VC4-xV
Check 10 GbE packets transport by means of VC4-xV (virtual concatenation).
Purpose
Check if the Virtual concatenated ETS cross-connection works properly with limited
•
capacity (7 VC4) of the Virtual concatenation group VC4-xV.
Let through data to check if the ports are properly connected to ODF
•
Alarms detection
•
Test instruments
Note:
Craft Terminal (E)
•
Pattern Generator/Error Detector (A)
•
x dB fixed attenuator
•
Accessories
Note:
Optical loop (K)
•
Single-mode or multi mode single-fiber splices (I) or (Q), according to the interface
•
type
Craft Terminal cable (L)
•
............................................................................................................................................................................................................................................................
3 - 2 8
Properties." Open the "Alarms" tag and check the presence of the TSF alarm (red
square).
the left of the port.
See
Table 3-1, "Instruments" (p. 3-2)
See
Table 3-2, "Accessories" (p. 3-2)
Local testing and operating sequence
PN 8DG08136CAAA
Issue 1 March 2008