Alcatel-Lucent 1850 TSS-320 Turn-Up And Commissioning Manual page 70

Transport service switch
Hide thumbs Also See for 1850 TSS-320:
Table of Contents

Advertisement

Tests and Measurements
............................................................................................................................................................................................................................................................
........................................................................................................................................................................................................................
9
Verify the insertion loss of each DEMUX channel, connecting the Power Meter to each
DEMUX output one-by-one, and checking the optical power each time.
........................................................................................................................................................................................................................
10
Connect each fiber to the related DEMUX output, then disconnect the other end from each
DWDM XFP, Rx side. Check the following:
The insertion loss of each fiber is 0.1 dB.
For each port, the received power is in the supported optical range (refer to
"SFP and XFP modules optical characteristics" (p.
........................................................................................................................................................................................................................
11
Connect each fiber to the related port/XFP, Rx side,
........................................................................................................................................................................................................................
12
Test the BER at a given bit rate, checking no errors for 5 minutes.
E
O
N D
........................................................................................................................................................
............................................................................................................................................................................................................................................................
3 - 4 4
S
F
T E P S
Local testing and operating sequence
4-16).
PN 8DG08136CAAA
Issue 1 March 2008