Alcatel-Lucent 1850 TSS-320 Turn-Up And Commissioning Manual page 44

Transport service switch
Hide thumbs Also See for 1850 TSS-320:
Table of Contents

Advertisement

Tests and Measurements
............................................................................................................................................................................................................................................................
By means of CT applications program the Laser-forced-ON on the optical port under test
(see
Chapter
PTx power test
........................................................................................................................................................................................................................
1
Connect power meter to the optical port output being tested.
Check LOS alarm on Error Detector.
Check that the optical power is within the range stated on the table reported in
4,
"SFP and XFP modules optical characteristics" (p.
........................................................................................................................................................................................................................
2
Switch off the LASER as specified in
OFF then ON" (p.
Program ALS Enabling port [see
OFF then ON" (p.
– Check that the LASER power is null.
– Check if the Tx optical power is null.
Repeat the test on each optical unit.
Preset the instrument to transmit a signal (based on the type of port used) with the
following requirements:
Bit rate
Code/interface (SFP)
Type
E
O
N D
........................................................................................................................................................
TL1 Procedure
By means of CT applications program the ALS-enabling on the looped optical port (see
Chapter
By means of CT applications program the laser-forced-ON on the optical port under test
(see
Chapter
............................................................................................................................................................................................................................................................
3 - 1 8
4,
"Standard procedures to turn the laser OFF then ON" (p.
4-14).
4-14)].
If the "ALS Automatic Restart" option is enabled, check if a power reset is
attempted after approximately 0 seconds. This condition must last approximately 2
seconds.
If these conditions do not occur, replace the optical unit under test.
155520 kbit/s
S-1.1, L-1.1, L-1.2
OC-3 optical
S
F
T E P S
4,
"Standard procedures to turn the laser OFF then ON" (p.
4,
"Standard procedures to turn the laser OFF then ON" (p.
Local testing and operating sequence
4-16).
Chapter
4,
"Standard procedures to turn the laser
Chapter
4,
"Standard procedures to turn the laser
See
Chapter 4
optical characteristics" (p.
4-14).
Chapter
,
"SFP and XFP modules
4-16).
4-14).
4-14).
PN 8DG08136CAAA
Issue 1 March 2008

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents