Alcatel-Lucent 1850 TSS-320 Turn-Up And Commissioning Manual page 64

Transport service switch
Hide thumbs Also See for 1850 TSS-320:
Table of Contents

Advertisement

Tests and Measurements
............................................................................................................................................................................................................................................................
........................................................................................................................................................................................................................
6
Connect the pattern generator/error detector and check that no errors are read
Pattern generator / Error Detector setup
Port type
Auto-negotiation
Frame length
Bandwidth
VLAN TAG
Optical interfaces (SFP) types (refer to
characteristics" (p. 4-16)
GbE SFP interface types (on PIM1GE)
E
O
N D
........................................................................................................................................................
DWDM ports test
Before starting the DWDM commissioning, be sure that the optical fibers are properly
cleaned.
All the single spans attenuation connecting the various link nodes, including the
acceptable margin, are given in the Design Project document (released by a Project
Manager) and in the Link Description Table (LDT).
The procedure is divided in two parts:
Local test
Link test
The node local test must be performed first. The link tests can be carried out after local
tests on all nodes.
............................................................................................................................................................................................................................................................
3 - 3 8
for details)
S
F
T E P S
Local testing and operating sequence
GbE
ON
1518 bytes
100%
Value set via CT, i.e. 10
Chapter
4,
"SFP and XFP modules optical
B&W = 1000 Base SX / 1000 Base LX / 1000 Base
ZX
CWDM = APD (C8L1-1D2) for long haul,
PIN (C8S1-1D2) for short haul
PN 8DG08136CAAA
Issue 1 March 2008