Tests and Measurements
............................................................................................................................................................................................................................................................
Frame length
Bandwidth
Optical interfaces (SFP) types (refer to
characteristics" (p. 4-16)
GbE SFP interface types (on PIM1GE)
........................................................................................................................................................................................................................
6
Check that all the frames received are the same of those transmitted and no alarms are
detected by the instrument for 5 minutes.
........................................................................................................................................................................................................................
7
Alarms detection — Perform the cross-connection above described.
From EML-USM -> Select "Equipment" -> "Data board Navigation." then insert login
and password. The Data CT starts.
– In the "1850TSS User Service Management.." window, double click on the board
– Select a local port. From the pop-up menu (click on the right button of the mouse),
– In "Ethernet port Configuration" window, select "Configuration" tag and set "Up"
– Select the port again. From the pop-up menu (click on the right button of the
Connect the Pattern Generator/Error Detector and check that the LOS alarm
disappears (green square) and that the on-board led related to the GbE port under test
is green.
Open the SONET loop to check the presence of the TSF alarm on the remote port, as
described in the following.
– Select a remote port. From the pop-up menu, select "Configure Ethernet port."
............................................................................................................................................................................................................................................................
PN 8DG08136CAAA
Issue 1 March 2008
for details)
(i.e., r1sr1/board#2). The local and remote Data ports are displayed.
select "Configure Ethernet port."
in "Admin. Status" field. Click on "OK."
mouse), select "Ethernet Port Properties." Open the "Alarms" tag and check the
presence of the LOS alarm (red square).
In "Ethernet port Configuration" window, select "Configuration" tag and set "Up"
in "Admin. Status" field. Click on "OK."
Local testing and operating sequence
1518 bytes
100%
Chapter
4,
"SFP and XFP modules optical
B&W = 1000 Base SX / 1000 Base LX / 1000 Base
ZX
CWDM = APD (C8L1-1D2) for long haul,
PIN (C8S1-1D2) for short haul
3 - 2 7