Tests and Measurements
............................................................................................................................................................................................................................................................
........................................................................................................................................................................................................................
4
Cross-connect the VC4-7V to one port of the 10 x 1 GbE PIM (PIM1GE), as shown in
Chapter
........................................................................................................................................................................................................................
5
Start transmitting at 100% of the available bandwidth
Pattern generator / Error Detector setup
Port type
Auto-negotiation
Frame length
Bandwidth
Optical interfaces (SFP) types (refer to
characteristics" (p. 4-16)
GbE SFP interface types (on PIM1GE)
........................................................................................................................................................................................................................
6
Check that all the frames received are the same of those transmitted and no alarms are
detected by the instrument for 5 minutes.
........................................................................................................................................................................................................................
7
Alarms detection — Perform the cross-connection described above.
From EML-USM -> Select "Equipment" -> "Data board Navigation," then insert login
and password. The Data CT starts.
– In the "1850TSS User Service Management.." window, double-click on the board
– Select a local port. From the pop-up menu (click on the right button of the mouse),
– In "Ethernet port Configuration" window, select "Configuration" tag and set "Up"
– Select the port again. From the pop-up menu (click on the right button of the
............................................................................................................................................................................................................................................................
PN 8DG08136CAAA
Issue 1 March 2008
4,
"Cross-connection between a local and a remote data port" (p.
for details)
(i.e., r1sr1/board#2). The local and remote Data ports are displayed.
select "Configure Ethernet port."
in "Admin. Status" field. Click on "OK."
mouse), select "Ethernet Port Properties." Open the "Alarms" tag and check the
presence of the LOS alarm (red square).
Local testing and operating sequence
GbE
ON
1518 bytes
100%
Chapter
4,
"SFP and XFP modules optical
B&W = 1000 Base SX / 1000 Base LX / 1000 Base
ZX
CWDM = APD (C8L1-1D2) for long haul,
PIN (C8S1-1D2) for short haul
4-12).