Tests and Measurements
............................................................................................................................................................................................................................................................
........................................................................................................................................................................................................................
5
Start transmitting at 10% of the available bandwidth
Pattern generator / Error Detector setup
Port type
Auto-negotiation
Frame length
Bandwidth
Optical interfaces (XFP) types (refer to
characteristics" (p. 4-16)
10GbE XFP interface types (on
PIM10GE)
........................................................................................................................................................................................................................
6
Check that all the frames received are the same of those transmitted and no alarms are
detected by the instrument for 5 minutes.
........................................................................................................................................................................................................................
7
Alarms detection — Perform the cross-connection described above.
From EML-USM, select "Equipment" -> "Data board Navigation," then insert login
and password. The Data CT starts.
– In the "1850TSS User Service Management.." window, double click on the board
– Select a local port. From the pop-up menu (click on the right button of the mouse),
– In "Ethernet port Configuration" window, select "Configuration" tag and set "Up"
– Select the port again. From the pop-up menu (click on the right button of the
Connect the Pattern Generator/Error Detector and check that the LOS alarm
disappears (green square) and that the on-board led related to the 10 GbE port under
test is green.
............................................................................................................................................................................................................................................................
3 - 3 2
for details)
(i.e., r1sr1/board#2). The local and remote Data ports are displayed.
select "Configure Ethernet port."
in "Admin. Status" field. Click on "OK."
mouse), select "Ethernet Port Properties." Open the "Alarms" tag and check the
presence of the LOS alarm (red square).