Tests and Measurements
............................................................................................................................................................................................................................................................
STATION-A
........................................................................................................................................................................................................................
5
With the pattern generator, send a fixed PRBS sequence
........................................................................................................................................................................................................................
6
Check that the error detector has read no errors.
........................................................................................................................................................................................................................
7
Increase the optical attenuation till errors are read on the error detector.
........................................................................................................................................................................................................................
8
Reduce attenuation until no errors are read.
........................................................................................................................................................................................................................
9
Disconnect the optical cable from the STM-n input port (point A in
connect it to the power meter input.
........................................................................................................................................................................................................................
10
Margin level must be minimum 4 dB better than the values reported in
87.
........................................................................................................................................................................................................................
11
Turn-on the laser through the CT (see
........................................................................................................................................................................................................................
12
Wait for 180 sec. and then read the Rx optical power.
The difference between the Rx optical power [see
(p.
3-59)] and the Rx optical power when introducing attenuation (as above explain) is the
"link margin."
........................................................................................................................................................................................................................
13
Repeat the check on the other port with "line port" function.
E
O
N D
........................................................................................................................................................
............................................................................................................................................................................................................................................................
PN 8DG08136CAAA
Issue 1 March 2008
S
F
T E P S
Point-to-point measures list and operating sequence
para. 4.6 on page
86).
"Rx Optical "line port" power check"
Figure
28) and
para 4.7 on page
3 - 6 3