REMOTE CONTROL
Remote control (CI-V) information
D Command table
Cmd�
Sub cmd�
Data
00
See p� 16�
01
See p� 16�
02*
See p� 16�
1
03*
See p� 16�
1
04*
See p� 16�
1
05*
See p� 16�
2
06*
See p� 16�
2
07
00
01
A0
B0
08*
2
00 00 ~ 00 99 Select the Memory channel
A0
00 00 ~ 01 00 Select the Memory group
09
0A
0B
0C*
1
See p� 17�
0D*
2
See p� 17�
0E
00
01
02
03
12
13
22
23
24
Ax*
2
(x=1 ~ 7)
Description
Send the frequency data
(transceive)
Send the mode data (transceive)
Read the band edge frequencies
Read the operating frequency
Read the operating mode
Set the operating frequency
Set the operating mode
Select the VFO mode
Select VFO A
Select VFO B
Equalize VFO A and VFO B
L When the split frequency
operation is OFF in the Memory
mode or the Call channel mode,
"FA" (NG) is returned�
Exchange VFO A and VFO B�
L When the split frequency
operation is OFF in the Memory
mode or the Call channel mode,
"FA" (NG) is returned�
Select the Memory mode
( Memory channel: 00 00 ~ 00 99
Call channel:
00 00 (144C1),
00 01 (144C2),
00 02 (430C1),
00 03 (430C2),
00 04 (1200C1),
00 05 (1200C2),
00 06 (2400C1),
00 07 (2400C2),
00 08 (5600C1),
00 09 (5600C2),
00 10 (10GC1),
00 11 (10GC2)
( Memory channel group:
00 00 ~ 00 99
Call channel group: 01 00)
Memory write
Memory copy to VFO
Memory clear
Read frequency offset
Send frequency offset
Cancel the scan
Start a Programmed/memory scan
Start a Programmed scan
Start a ∂F scan
Start a Fine programmed scan
Start a Fine ∂F scan
Start a Memory scan
Start a Select memory scan
Start a Mode Select scan
Select ∂F scan span
( x=1 (±5kHz),
x=2 (±10kHz),
x=3 (±20kHz),
x=4 (±50kHz),
x=5 (±100kHz), x=6 (±500kHz),
x=7 (±1MHz))
Cmd�
Sub cmd�
0E
B0*
2
B1*
2
01 ~ 03
B2*
00 ~ 03
2
D0*
2
D3*
2
0F
00*
1
01*
1
11*
1
12*
1
13*
1
00*
2
01*
2
10*
2
11*
2
12*
2
13*
2
10*
00 ~ 12
11*
00
10
13
00
01
02
14*
01
00 00 ~ 02 55 Send/read the AF level
02
00 00 ~ 02 55 Send/read the RF gain level
03
00 00 ~ 02 55 Send/read the squelch level
06
00 00 ~ 02 55 Send/read the NR level
07
00 00 ~ 02 55 Send/read [TWIN PBT] (PBT1)
3
Data
Description
Clear the Select channel setting
Set as select channel
L The previously set number by
CI-V is set after turning power
ON, or "1" is selected if no
selection is performed�
Set the channel as a Select channel
(01=SEL1, 02=SEL2, 03=SEL3)
Set the Select memory scan
channel
( 00=ALL, 01=SEL1, 02=SEL2,
03=SEL3)
Set Scan resume OFF
Set Scan resume ON (Close&Delay)
Read Split OFF setting
Read Split ON setting
Read DUP– operation
Read DUP+ operation
Read DD Repeater Simplex mode
(RPS)
Set Split function OFF
Set Split function ON
Set the simplex operation
Set DUP– operation
Set DUP+ operation
Set DD Repeater Simplex mode
(RPS)
Send/read the tuning step
( 00=OFF (10Hz or 1Hz)
01=100Hz,
02=500Hz,
03=1kHz,
04=5kHz,
05=6�25kHz,
06=10kHz,
07=12�5kHz,
08=20kHz,
09=25kHz,
10=50kHz,
11=100kHz,
12=250kHz)
Send/read attenuator OFF setting
Send/read 10 dB attenuator setting
L You can set in the 144/430/1200
MHz bands�
Speech all data by voice synthesizer
(S meter level, frequency, and mode)
Speech the operating frequency and
S meter level by voice synthesizer
Speech the operating mode by
voice synthesizer
L The mode is announced after
the ongoing speech�
(00 00=Minimum ~ 02 55=Maximum)
(00 00=Minimum ~ 02 55=Maximum)
(00 00=Minimum ~ 02 55=Maximum)
(00 00=0% ~ 02 55=100%)
position
( 00 00=max� Counter Clockwise ~
01 28=center ~ 02 55=max� Clockwise)
Need help?
Do you have a question about the IC-905 and is the answer not in the manual?
Questions and answers