Install the photo conductor unit with the tape still attached. Align the tip of
the photo conductor unit with the opening, and then slowly insert the unit,
until it stops.
Take care that nothing comes into contact with the surface of the photo con-
ductor unit.
K
Use a finger to push the label with three green lines, and then push in the
photo conductor unit, until it clicks into position. If the installation fails,
the small, pentagonal window turns red.
L
Hold the photo conductor unit firmly in place, and then pull out the tape.
• Remember to pull out the tape. Malfunctions occur if you attempt to print
while the tape is still attached.
• The removed tape is dirty. Be careful not to let it touch your hands or
clothes.