Connection Details - Shure DCS 6000 User Manual

Digital conference system conferencing and discussion systems
Hide thumbs Also See for DCS 6000:
Table of Contents

Advertisement

DCS 6000 Digital Conference System
PS CU Power Supply
Main Voltage
Max. consumption
Total supply power
Input current
In-rush current
Standby consumption

Connection Details

Mains
Blue
Brown
Green/Yellow
DCS-LAN Chain
The DCS 6000 system uses shielded Cat5e, Cat6
or Cat7 F/UTP or U/FTP cables with shielded RJ45
connectors.
EIA 568-B wiring shall be used.
Important: The names of Cat5/6/7 cable type have
changed.
Old name
FTP
STP
UTP
Important: Use only F/UTP or U/FTP (shielded) cables
and shielded RJ45 connectors and not U/UTP cable,
which are unshielded.
How to wire a Cat5e (EIA 568-B) cable to a RJ45
con.:
Pin
Function
Connector #1
1
In-going +
ORG/WHT
2
In-going -
ORG
3
+48V
GRN/WHT
4
0V
BLU
5
0V
BLU/WHT
6
+48V
GRN
7
Outgoing -
BRN/WHT
8
Outgoing +
BRN
.. 100-240V, 50-60 Hz nominal
.................................. 175 W
.... 144W (power factor: >0.9)
................. max. 4A@115V AC
................. max. 2A@230V AC
.................... max. 40A@115V
................... max. 80A@230V
............... <0,5W (no load)
Neutral
Live
Earth (Ground)
New name
F/UTP
U/FTP
U/UTP
Connector #2
ORG/WHT
ORG
GRN/WHT
BLU
BLU/WHT
GRN
BRN/WHT
BRN
Supply voltage for CU
Efficiency typical
Weight
Dimensions (W x H x D) ............ 99 x 52 x 180 mm
Approvals
Specifications are subject to change without
notice.
Important: If other color codes are used then the
four pairs are connected as follows:
Pair 2:
Pin 1 & 2
Pair 3:
Pin 3 & 6
Pair 1:
Pin 4 & 5
Pair 4:
Pin 7 & 8
The phase of the pairs must be correct and the
wiring spec. as stated in Cat5e (EIA 568-B)
have to be followed.
Note: Cat6 and Cat7 cables can normally only be
terminated in sockets (female) and not in cable
plugs.
Cat6 and Cat7 can thus only be used for feeding
cables terminating in wall outlets or patch panels.
Analog Audio Out
XLR3 male
Pin
Signal
1
Earth
2
Signal +
3
Signal –
Analog Audio In
XLR3 female
Pin
Signal
1
Earth
2
Signal +
3
Signal –
Emergency switch
Terminal block
50
........... 48V/3A @ 40 deg C
(De-rate linearly to 50% @ 60 deg C)
................................ 87%
.............................. 935 g
... CE, KC, CCC, cULus, TÜV
Cable type
2 x 0.25 mm2
shielded.
Cable type
2 x 0.25 mm2
shielded.
User Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu 6105Cu 6110

Table of Contents