Connection Details; Accessories - Shure DM 6680 P User Manual

Conferencing and discussion systems
Table of Contents

Advertisement

DCS 6000 Digital Conference System

Connection Details

DCS-LAN Chain
The DCS 6000 system uses shielded Cat5e, Cat6
or Cat7 F/UTP or U/FTP cables with shielded RJ45
connectors.
EIA 568-B wiring shall be used.
Important: The names of Cat5/6/7 cable type have
changed.
Old name
FTP
STP
UTP
Important: Use only F/UTP or U/FTP (shielded) cables
and shielded RJ45 connectors and not U/UTP cable,
which are unshielded.
How to wire a Cat5e (EIA 568-B) cable to a RJ45
con.:
Pin
Function
1
In-going +
ORG/WHT
2
In-going -
ORG
3
+48V
GRN/WHT
4
0V
BLU
5
0V
BLU/WHT
6
+48V
GRN
7
Outgoing -
BRN/WHT
8
Outgoing +
BRN
Important: If other color codes are used then the four
pairs are connected as follows:
Pair 2:
Pin 1 & 2
Pair 3:
Pin 3 & 6
Pair 1:
Pin 4 & 5
Pair 4:
Pin 7 & 8
The phase of the pairs must be correct and the
wiring spec. as stated in Cat5e (EIA 568-B) have
to be followed.

Accessories

Cat5e Connection Cables (AWG24)
EC 6001-0.5 .................. Connection Cable 0.5 m
EC 6001-01 ..................... Connection Cable 1 m
EC 6001-02 ..................... Connection Cable 2 m
EC 6001-05 ..................... Connection Cable 5 m
New name
F/UTP
U/FTP
U/UTP
Connector #1
Connector #2
ORG/WHT
ORG
GRN/WHT
BLU
BLU/WHT
GRN
BRN/WHT
BRN
Note: Cat6 and Cat7 cables can normally only be
terminated in sockets (female) and not in cable plugs.
Cat6 and Cat7 can thus only be used for feeding cables
terminating in wall outlets or patch panels.
HD15 connector
The HD15 connector on the MU 6040 D/C and MU
6042 has the following PIN layout:
Pin
Signal
1
- Loudspeaker output
2
Speak 1 LED
3
Request 1 LED
4
ON/OFF 1 button input
5
Delegate OFF button /
*ON/OFF 2 button input
6
Optional input
7
+ Loudspeaker output
(8 ohm)
8
NC
9
*Speak 2 LED
10
+ lamp
11
+5V
12
0V
13
MIC ground
14
+ MIC
15
*Request 2 LED
* Only connected on MU 6042
Connection of GM 652x to AM/MU 6040
AM/MU 6040 – HD 15
Pin
Comments
10
+ lamp
12
0V
13
MIC ground
14
+ MIC
EC 6001-10 ................... Connection Cable 10 m
EC 6001-20 ................... Connection Cable 20 m
EC 6001-50 ................... Connection Cable 50 m
37
User Manual
Cable type
DIS type:
#2029 or according
to the specific
installation.
GM 652x – XLR 3P
Pin
Comments
4
House
3
1
2