DCS 6000 Digital Conference System

Technical Specifications

System Specification

Power consumption ............................... max. 10W
Temperature to guarantee specified performance
........... 5 Deg C. to 40 Deg C. (35 to 80% humidity)
Storage temperature
........ -20 Deg C. to 60 Deg C. (10 to 80% humidity)
Weight ..........................................................1 kg
Dimensions (W x H x D) ............ 264 x 42 x 128 mm

Connection Details

DCS-LAN Chain
The DCS 6000 system uses shielded Cat5e, Cat6
or Cat7 F/UTP or U/FTP cables with shielded RJ45
connectors.
EIA 568-B wiring shall be used.
Important: The names of Cat5/6/7 cable type have
changed.
Old name
FTP
STP
UTP
Important: Use only F/UTP or U/FTP (shielded) cables
and shielded RJ45 connectors and not U/UTP cable,
which are unshielded.
How to wire a Cat5e (EIA 568-B) cable to a RJ45
con.:
Pin
Function
1
In-going +
ORG/WHT
2
In-going -
ORG
3
+48V
GRN/WHT

Accessories

Cat5e Connection Cables (AWG24)
EC 6001-0.5 ....................... Connection Cable 0.5 m
EC 6001-01 ........................... Connection Cable 1 m
EC 6001-02 ........................... Connection Cable 2 m
New name
F/UTP
U/FTP
U/UTP
Connector #1
Connector #2
ORG/WHT
ORG
GRN/WHT
Dimensions with 19" brackets .. 482,6 x 44 x 128 mm
Connectors
DCS-LAN loop through ....................... 2 pieces RJ45
DCS-LAN repeated output .................. 4 pieces RJ45
Specifications are subject to change without
notice.
4
0V
5
0V
6
+48V
7
Outgoing -
8
Outgoing +
Important: If other color codes are used then the
four pairs are connected as follows:
Pair 2:
Pin 1 & 2
Pair 3:
Pin 3 & 6
Pair 1:
Pin 4 & 5
Pair 4:
Pin 7 & 8
The phase of the pairs must be correct and the
wiring spec. as stated in Cat5e (EIA 568-B) have
to be followed.
Note: Cat6 and Cat7 cables can normally only be
terminated in sockets (female) and not in cable plugs.
Cat6 and Cat7 can thus only be used for feeding cables
terminating in wall outlets or patch panels.
EC 6001-05 ......................... Connection Cable 5 m
EC 6001-10 ....................... Connection Cable 10 m
EC 6001-20 ....................... Connection Cable 20 m
EC 6001-50 ....................... Connection Cable 50 m
13
BLU
BLU
BLU/WHT
BLU/WHT
GRN
GRN
BRN/WHT
BRN/WHT
BRN
BRN