Shure DCS 6000 User Manual page 38

Digital conference system conferencing and discussion systems
Hide thumbs Also See for DCS 6000:
Table of Contents

Advertisement

DCS 6000 Digital Conference System
#
Menu
21.
Settings
Description
Voice Activation –
Those settings determines the
behavior of the system when
working in VOX mode
The 'Voice detection threshold'
can be set to values ranging
from '-12 to '8' in steps of '1'.
The default value is '0'.
Setting to a lower value
makes the microphone more
sensitive.
The 'Voice detection release
time' can be set to values
from 1 to 10 seconds in 0.5
sec step.
This setting is used for setting
the time from the delegate
stops talking until the
microphone turns off. The
default value is 4 sec.
When "Book Drop" Feature is
enabled a short 'unwanted'
noise will only make the
microphone to open a few
seconds.
"Last Mic Stays Open" feature
is used when the DCS 6000
system is used for video or
audio conferences where
equipment with echo-
canceling feature is in use.
Auto Off –
When 'Microphone Auto Off' is
set to 'On' a Conference unit
will automatic turn off the
microphone when the
delegate stops talking. The
time is determined by the
'Auto Off time' setting.
The 'Automatic Off Time' sets
the time from the delegate
stops speaking until the
microphone turns off. The
value can be set from 5 to 60
seconds in 5 second steps.
The default value is 5 sec.
When the system is set to
VOX mode Auto Off settings
are disabled.
38
User Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu 6105Cu 6110

Table of Contents