Gas & Electric Dryers; Gas Burner Coils; Burner Ignitor - Whirlpool ADVANTECH CAE2761K Installation, Operation And Service Instructions

Washers/ freestanding dryers/ stack dryers
Table of Contents

Advertisement

Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.

GAS BURNER COILS

Refer to page 4-50 for the procedure for ser-
vicing the gas burner assembly.
1. Unplug dryer or disconnect power.
2. Turn off gas supply to dryer.
3. Disconnect the wire connectors from the
coil terminals.
4. Set the ohmmeter to the R X 100 scale.
5. Touch the ohmmeter test leads to the
indicated coil terminals. The meter should
indicate as follows:
Pins 1 & 2 = 1300 to 1400 Ω
Pins 1 & 3 = 500 to 600 Ω
Pins 4 & 5 = 1200 to 1300 Ω
1 2 3
GAS & ELECTRIC DRYERS
Electrical Shock Hazard
4 5
WARNING

BURNER IGNITOR

Refer to page 4-50 for the procedure for ser-
vicing the gas burner assembly.
1. Unplug dryer or disconnect power.
2. Turn off gas supply to dryer.
3. Disconnect the ignitor wire connector from
the main harness connector.
4. Set the ohmmeter to the R X 1 scale.
5. Touch the ohmmeter test leads to the
2-wire connector pins. The meter should
indicate between 50 and 250 Ω.
Burner Ignitor
5-7
2-Wire Connector

Advertisement