It is also recommended that a separate circuit serving only this
dryer be provided.
GROUNDING INSTRUCTIONS
For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING:
Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE INSTRUCTIONS

Gas Supply Requirements

Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
//static-data2.manualslib.com/manual/190510/Whirlpool-Cabrio-W10164752a.html?page=7 (2 of 7)3/20/2018 3:42:23 AM
WARNING
Explosion Hazard
LP gas conversion:
Conversion must be made by a qualified technician.
No attempt shall be made to convert the appliance from the gas
specified on the model/serial rating plate for use with a different gas
without consulting your gas company. For information on ordering
an LP conversion kit, please refer to the "Assistance or Service"
section. Ask for Part Number 49572.
Gas Supply Line:
Must include
/ " NPT minimum plugged tapping accessible for
1 8
test gauge connection, immediately upstream of the gas
connection to the dryer (see illustration).
/ " IPS pipe is recommended.
1
2
/ " approved aluminum or copper tubing is acceptable for
3
8
lengths under 20 ft (6.1 m) if local codes and gas supplier
permit.
If you are using Natural gas, do not use copper tubing.
/
/ " NPT adapter fitting between dryer pipe and
" flare x
3
3
8
8
approved tubing.
Lengths over 20 ft (6.1 m) should use larger tubing and a
different size adapter fitting.
If your dryer has been converted to use LP gas,
compatible copper tubing can be used. If the total length of the
supply line is more than 20 ft (6.1 m), use larger pipe.
NOTE: Pipe-joint compounds that resist the action of LP gas
must be used. Do not use TEFLON
Must include a shutoff valve:
In the U.S.A.:
An individual manual shutoff valve must be installed within
six (6) feet (1.8 m) of the dryer in accordance with the National
Fuel Gas Code, ANSI Z223.1.
In Canada:
An individual manual shutoff valve must be installed in
accordance with the B149.1, Natural Gas and Propane
Installation Code. It is recommended that an individual
manual shutoff valve be installed within six (6) feet (1.8 m) of
the dryer.
/ "
3
8
/
" LP
3
8
tape.
®†