Whirlpool ADVANTECH CAE2761K Installation, Operation And Service Instructions page 168

Washers/ freestanding dryers/ stack dryers
Table of Contents

Advertisement

SUPRESSOR REPLACEMENT EMS1000 and ADVANTECH™ WASHERS
1. Remove the 2 control panel screws at the base of the console and rotate the console open into the service position.
2. Remove the electrical tape that secures the suppressor/quencher assembly to the wiring harness.
3. Unplug the suppressor from the power cord connector and the wiring harness connector.
NOTE: On washers it is possible to plug the wiring harness connector directly into the power cord connector BYPASSING
the suppressor. On dryers the unit will operate without the suppressor plugged in. This will expose the control to line
transients (voltage spikes) that can damage the control. Internal switch closures may also cause the control to reset.
NEVER eliminate the supressor or quencher!
SUPRESSOR REPLACEMENT 27" EMS1000 and ADVANTECH™ DRYERS
1. Disconnect electrical power.
2. On gas dryers remove the power cord access panel from the rear of the dryer.
3. Remove the power cord from the backsplash.
4. On electric dryers remove the control panel mounting screws and rotate the console open into the service position.
5. Unplug the suppressor from the power cord and wiring harness and replace.
6. Replace all panels and reconnect electrical power.
NOTE: On 29" Dryers remove the rear access panel to gain access to the suppressor assembly located underneath the
terminal block.
SUPPRESSOR
HARNESS AND
POWER CORD
CONNECTORS
— 4 —
UNPLUG
SUPPRESSOR AT
POWER CORD AND
HARNESS
CONNECTION
SUPPRESSOR
BYPASSED

Advertisement

Table of Contents
loading

Table of Contents