Removing A Heat-Sink Retention Module - Lenovo ThinkServer TD200x Hardware Maintenance Manual

Hide thumbs Also See for ThinkServer TD200x:
Table of Contents

Advertisement

Removing a heat-sink retention module

To remove a heat-sink retention module, complete the following steps:
10. If you are instructed to return the heat-sink retention module, follow all
1
Alignment triangle
1. Read the safety information that begins on page 5.
2. Turn off the server and all attached devices; then, disconnect all power cords
and external cables.
3. Carefully turn the server on its side so that it is lying flat, with the cover facing
up.
Attention:
Do not allow the server to fall over.
4. Unlock and remove the side cover (see "Removing the left-side cover" on page
159).
5. Remove the power supply or power supplies from the power-supply cage (see
"Removing a hot-swap power supply" on page 176).
6. Rotate the power-supply cage to its open position (see "Opening the
power-supply cage" on page 160).
7. Remove the air baffle (see "Removing the air baffle" on page 171).
8. Remove the heat sink (see "Removing a microprocessor and heat sink" on
page 220).
9. Using a Phillips screwdriver, remove the four screws that secure the heat-sink
retention module to the system board; then, lift the heat-sink retention module
from the system board.
packaging instructions, and use any packaging materials for shipping that are
supplied to you.
Chapter 7. Installing optional devices and replacing customer replaceable units
229