Installing The 2.5-Inch Disk Drive Cage - Lenovo ThinkServer TD200x Hardware Maintenance Manual

Hide thumbs Also See for ThinkServer TD200x:
Table of Contents

Advertisement

Installing the 2.5-inch disk drive cage

To install a 2.5-inch hard disk drive cage, complete the following steps:
10. Return the power-supply cage to its closed position (see "Closing the
11. Install the power supplies (see "Installing a hot-swap power supply" on page
206
ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Hardware Maintenance Manual
1
2.5-inch hard disk drive cage
2
2.5-inch hot-swap drive
1. Touch the static-protective package that contains the 2.5-inch disk drive cage
to any unpainted metal surface on the server; then, remove the drive cage
from the package.
2. Install both 2.5-inch disk drive backplanes in the back of the drive cage (see
"Installing a 2.5-inch disk drive backplane" on page 202).
3. Slide the 2.5-inch disk drive cage into the opening in the front of the server;
then, press drive cage in until the release latches click into place.
4. Install any hot-swap hard disk drives that were removed from the drive cage
(see "Installing a 2.5-inch hot-swap hard disk drive" on page 198).
5. Close the bezel (see "Closing the bezel" on page 153).
6. Carefully turn the server on its side so that it is lying flat, with the cover facing
up.
Attention:
Do not allow the server to fall over.
7. Connect the cables to the 2.5-inch disk drive backplane (see "SAS backplane
connectors" on page 141 and "Internal cable routing and connectors" on page
165).
8. Install the fan-cage assembly (see "Installing the fan-cage assembly" on page
174).
9. Install the air baffle (see "Installing the air baffle" on page 172).
power-supply cage" on page 162).
177).

Advertisement

Table of Contents
loading

Table of Contents