Table 4. DSA messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 8, "Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823," on page 239 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a Trained
service technician.
Message
number
Component
264-906-000
Tape Drive
405-901-xxx
Broadcom
Ethernet
Device
405-901-xxx
Broadcom
Ethernet
Device
120
ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Hardware Maintenance Manual
Test
State
Description
Tape Drive
Failed
Unrecognized
Test
error.
Test Control
Failed
Registers
Test MII
Failed
Registers
Action
1. Clean the tape drive using the appropriate
cleaning media and install new media.
2. Run the test again.
3. Clear the error log.
4. Run the test again.
5. Make sure that the firmware is at the latest
level. Software for tape drives and libraries can
be found at http://www.ibm.com/systems/
support/.
6. Run the test again.
7. If the failure remains, go to the Lenovo Web site
for more troubleshooting information at
http://www.lenovo.com/support.
1. Make sure that the component firmware is at the
latest level. The installed firmware level is shown
in the DSA log in the Firmware/VPD section for
this component. For more information, see
"Updating the firmware" on page 267.
2. Run the test again.
3. Replace the component that is causing the error.
If the error is caused by an adapter, replace the
adapter. Check the PCI Information and Network
Settings information in the DSA log to determine
the physical location of the failing component.
4. If the failure remains, go to the Lenovo Web site
for more troubleshooting information at
http://www.lenovo.com/support.
1. Make sure that the component firmware is at the
latest level. The installed firmware level is shown
in the DSA log in the Firmware/VPD section for
this component. For more information, see
"Updating the firmware" on page 267.
2. Run the test again.
3. Replace the component that is causing the error.
If the error is caused by an adapter, replace the
adapter. Check the PCI Information and Network
Settings information in the DSA log to determine
the physical location of the failing component.
4. If the failure remains, go to the Lenovo Web site
for more troubleshooting information at
http://www.lenovo.com/support.