v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 8, "Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823," on page 239 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
0051009
No memory detected
005100A
No usable memory detected
0058001
PFA threshold exceeded
0058007
DIMM population is unsupported
0058008
DIMM failed memory test
00580A1
Invalid DIMM population for mirroring mode
32
ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Hardware Maintenance Manual
Action
1. Make sure that the server contains DIMMs.
2. Reseat the DIMMs.
3. Install DIMMs in the correct sequence (see
"Installing a memory module" on page 213).
1. Make sure that the server contains DIMMs.
2. Reseat the DIMMs.
3. Install DIMMs in the correct sequence (see
"Installing a memory module" on page 213).
4. Clear CMOS memory to re-enable all the memory
connectors.
1. Update the firmware (see"Updating the firmware"
on page 267).
2. Reseat the DIMMs and run the memory test.
3. Replace the failing DIMM, which is indicated by a
lit LED on the system board.
1. Reseat the DIMMs, and then restart the server.
2. Remove the lowest-numbered DIMM pair of those
that are identified, replace it with an identical pair
of known good DIMMs, and then restart the
server. Repeat as necessary. If the failures
continue, go to step 4.
3. Return the removed DIMMs, one pair at a time, to
their original connectors, restarting the server
after each pair, until a pair fails. Replace the
DIMMs in the failed pair with identical known
good DIMMs, restarting the server after each
DIMM is installed. Replace the failed DIMM.
Repeat this step until you have tested all
removed DIMMs.
4. (Trained service technician only) Replace the
system board.
1. Reseat the DIMMs, and then restart the server.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. DIMMs
b. (Trained service technician only) System
board
1. If a fault LED is lit, resolve the failure.
2. Install the DIMMs in the correct sequence (see
"Installing a memory module" on page 213).