Lenovo ThinkServer TD200x Hardware Maintenance Manual page 123

Hide thumbs Also See for ThinkServer TD200x:
Table of Contents

Advertisement

Table 4. DSA messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 8, "Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823," on page 239 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a Trained
service technician.
Message
number
Component
202-802-xxx
Memory
202-901-xxx
Memory
215-801-xxx
Optical Drive
Test
State
Description
Memory
Failed
General error:
Stress Test
memory size is
insufficient to
run the test.
Memory
Failed
Test failure.
Stress Test
Aborted
Unable to
v Verify
communicate
Media
with the device
Installed
driver.
v Read/
Write Test
v Self-Test
Messages
and actions
apply to all
three tests.
Action
1. Make sure that all memory is enabled by
checking the Available System Memory in the
Resource Utilization section of the DSA log. If
necessary, enable all memory in the Setup utility
(see "Using the Setup Utility" on page 252).
2. Make sure that the DSA code is at the latest
level.
3. Run the test again.
4. Run the standard memory test to validate all
memory.
5. If the failure remains, go to the Lenovo Web site
for more troubleshooting information at
http://www.lenovo.com/support.
1. Run the standard memory test to validate all
memory.
2. Make sure that the DSA code is at the latest
level.
3. Turn off the system and disconnect it from
power.
4. Reseat the DIMMs.
5. Reconnect the system to power and turn on the
system.
6. Run the test again.
7. If the failure remains, go to the Lenovo Web site
for more troubleshooting information at
http://www.lenovo.com/support.
1. Make sure that the DSA code is at the latest
level.
2. Run the test again.
3. Check the drive cabling at both ends for loose
or broken connections or damage to the cable.
Replace the cable if it is damaged.
4. Run the test again.
5. For additional troubleshooting information, go
to http://www.ibm.com/support/
docview.wss?uid=psg1MIGR-41559.
6. Run the test again.
7. Make sure that the system firmware is at the
latest level. The installed firmware level is
shown in the DSA log in the Firmware/VPD
section for this component. For more
information, see "Updating the firmware" on
page 267.
8. Run the test again.
9. Replace the CD/DVD drive.
10. If the failure remains, go to the Lenovo Web
site for more troubleshooting information at
http://www.lenovo.com/support.
Chapter 5. Diagnostics
115