Removing A Voltage Regulator Module - Lenovo ThinkServer TD200x Hardware Maintenance Manual

Hide thumbs Also See for ThinkServer TD200x:
Table of Contents

Advertisement

Removing a voltage regulator module

To remove a voltage regulator module (VRM), do the following:
10. Pull the VRM out of the connector.
11. If you are instructed to return the VRM, follow all packaging instructions, and
1
Microprocessor 2 VRM
2
Heat sink 2
3
VRM connector
1. Read the safety information (see Chapter 2, "Safety information," on page 5).
2. Turn off the server and peripheral devices, and disconnect the power cords
and all external cables.
3. Carefully turn the server on its side so that it is lying flat, with the cover facing
up.
Attention:
Do not allow the server to fall over.
4. Unlock and remove the left-side cover (see "Removing the left-side cover" on
page 159).
5. Remove the hot-swap power supply or power supplies from the power-supply
cage (see "Removing a hot-swap power supply" on page 176).
6. Rotate the power-supply cage to its open position (see "Opening the
power-supply cage" on page 160).
7. Remove the air baffle (see "Removing the air baffle" on page 171).
8. Locate the voltage regulator module next to microprocessor 2.
9. Open the retaining clips on each end of the VRM connector.
use any packaging materials for shipping that are supplied to you.
Chapter 7. Installing optional devices and replacing customer replaceable units
181

Advertisement

Table of Contents
loading

Table of Contents