Removing The 2.5-Inch Disk Drive Cage - Lenovo ThinkServer TD200x Hardware Maintenance Manual

Hide thumbs Also See for ThinkServer TD200x:
Table of Contents

Advertisement

Removing the 2.5-inch disk drive cage

To remove the 2.5-inch hard disk drive cage, complete the following steps.
10. Remove all of the disk drives from the 2.5-inch disk drive cage (see "Removing
11. Disconnect the cables from the 2.5-inch disk drive backplane.
12. Press both drive cage release latches inward; then, pull the drive cage out of
204
ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Hardware Maintenance Manual
1
2.5-inch hard disk drive cage
2
2.5-inch hot-swap drive
1. Read the safety information that begins on page 5..
2. Turn off the server and peripheral devices, and disconnect the power cords
and all external cables.
3. Carefully turn the server on its side so that it is lying flat, with the cover facing
up.
Attention:
Do not allow the server to fall over.
4. Unlock and remove the left-side cover (see "Removing the left-side cover" on
page 159).
5. Remove the power supply or power supplies from the power-supply cage (see
"Removing a hot-swap power supply" on page 176).
6. Rotate the power-supply cage to its open position (see "Opening the
power-supply cage" on page 160).
7. Remove the air baffle (see "Removing the air baffle" on page 171).
8. Remove the fan-cage assembly (see "Removing the fan-cage assembly" on
page 173).
9. Turn the server upright and open the bezel (see "Opening the bezel" on page
152).
a 2.5-inch hot-swap hard disk drive" on page 197).
the front of server.

Advertisement

Table of Contents
loading

Table of Contents