Lenovo ThinkServer TD200x Hardware Maintenance Manual page 225

Hide thumbs Also See for ThinkServer TD200x:
Table of Contents

Advertisement

The following illustration shows how to install DIMMs on the system board.
Attention:
Static electricity that is released to internal server components when
the server is powered on might cause the server to stop, which might result in the
loss of data. To avoid this potential problem, always use an electrostatic-discharge
wrist strap or other grounding system when you work inside the server with the
power on.
To install a DIMM, do the following:
1. Read the safety information that begins on page 5.
2. Turn off the server and peripheral devices; then, disconnect the power cords
and all external cables.
3. Remove the left-side cover (see "Removing the left-side cover" on page 159).
4. Remove the hot-swap power supply or power supplies from the server.
5. Pull up the power-supply cage handle, then swing the power-supply cage out
of the server (see"Opening the power-supply cage" on page 160 for more
information).
6. Remove the air baffle from the server (see "Removing the air baffle" on page
171 for more information).
7. Open the retaining clip on each end of the DIMM connector.
Attention:
To avoid breaking the DIMM retaining clips or damaging the
DIMM connectors, open and close the clips gently.
8. Touch the static-protective package containing the DIMM to any unpainted
metal surface on the outside of the server. Then, remove the DIMM from the
package.
9. Turn the DIMM so that the DIMM keys align correctly with the connector.
Chapter 7. Installing optional devices and replacing customer replaceable units
217

Advertisement

Table of Contents
loading

Table of Contents