v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 8, "Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823," on page 239 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
ENET[0] DHCP-HSTN=%1, DN=%2,
IP@=%3, SN=%4, GW@=%5,
DNS1@=%6.
(%1 = CIM_DNSProtocolEndpoint.
Hostname; %2 =
CIM_DNSProtocolEndpoint.
DomainName; %3 =
CIM_IPProtocolEndpoint.
IPv4Address; %4 =
CIM_IPProtocolEndpoint.
SubnetMask; %5 = IP address,
xxx.xxx.xxx.xxx; %6 = IP address,
xxx.xxx.xxx.xxx)
ENET[0] IP-Cfg:HstName=%1,
IP@%2, NetMsk=%3, GW@=%4.
(%1 = CIM_DNSProtocolEndpoint.
Hostname; %2 =
CIM_StaticIPSettingData.
IPv4Address; %3 =
CIM_StaticIPSettingData.
SubnetMask; %4 =
CIM_StaticIPSettingData.
DefaultGatewayAddress)
LAN: Ethernet[0] interface is no
longer active.
LAN: Ethernet[0] interface is now
active.
DHCP setting changed to by user
%1.
(%1 = user ID)
IMM: Configuration %1 restored from
a configuration file by user %2.
(%1 = CIM_ConfigurationData.
ConfigurationName; %2 = user ID)
Watchdog %1 Screen Capture
Occurred.
(%1 = OS Watchdog or Loader
Watchdog)
60
ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Hardware Maintenance Manual
Info
The DHCP server has
assigned an IMM IP address
and configuration.
Info
An IMM IP address and
configuration have been
assigned using client data.
Info
The IMM Ethernet interface
has been disabled.
Info
The IMM Ethernet interface
has been enabled.
Info
A user has changed the
DHCP mode.
Info
A user has restored the IMM
configuration by importing a
configuration file.
Error
An operating-system error
has occurred, and the
screen capture was
successful.
No action; information only.
No action; information only.
No action; information only.
No action; information only.
No action; information only.
No action; information only.
1. Reconfigure the watchdog
timer to a higher value.
2. Make sure that the IMM
Ethernet over USB interface
is enabled.
3. Reinstall the RNDIS or
cdc_ether device driver for
the operating system.
4. Disable the watchdog.
5. Check the integrity of the
installed operating system.

Advertisement