v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 8, "Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823," on page 239 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
3058004
Three boot failures
3108007
System configuration restored to default
settings
3138002
Boot configuration error
3808000
IMM communication failure
3808002
Error updating system configuration to IMM
3808003
Error retrieving system configuration from
IMM
3808004
IMM system event log full
36
ThinkServer TD200x Types 3719, 3821, 3822, and 3823: Hardware Maintenance Manual
Action
1. Undo any recent system changes, such as new
settings or newly installed devices.
2. Make sure that the server is attached to a reliable
power source.
3. Remove all hardware that is not listed on the
ServerProven Web site.
4. Make sure that the operating system is not
corrupted.
5. Run the Setup utility, save the configuration, and
then restart the server.
Information only. This is message is usually
associated with the CMOS battery clear event.
1. Remove any recent configuration changes that
you made in the Setup utility.
2. Run the Setup utility, select Load Default
Settings, and save the settings.
1. Remove power from the server for 30 seconds,
and then reconnect the server to power and
restart it.
2. Update the IMM firmware.
3. (Trained service technician only) Replace the
system board.
1. Remove power from the server, and then
reconnect the server to power and restart it.
2. Run the Setup utility and select Save Settings.
3. Update the firmware.
1. Remove power from the server, and then
reconnect the server to power and restart it.
2. Run the Setup utility and select Save Settings.
3. Update the IMM firmware.
v When out-of-band, use the IMM Web interface or
IPMItool to clear the logs from the operating
system.
v When using the local console:
1. Run the Setup utility.
2. Select System Event Logs.
3. Select Clear System Event Log.
4. Restart the server.