To fit.
1. Locate the bottom corners of the window assembly.
2. Gently push the window assembly into place and
secure with the window clamping brackets. The
window clamping brackets have a raised 'stop' that will
prevent them being rotated too far.

16.9 To remove the fuel effect.

All of the fuel effect components except the front coal and ceramic walls can be
removed by simply removing the window assembly as in this section 16.8. If the front
coal or ceramic walls are to be replaced it will be necessary to remove the window
frame and window assembly as in 16.7.
1. Remove the fuel effect in the reverse order to that shown for fitting in the ceramic
guide. The ceramic fuel effect may cause staining / discolouration to decorative
surfaces. It is therefore advisable to protect decorative surfaces.
2. Replace in the reverse order.

16.10 To remove the ceramic side walls.

1. Remove the window frame and window assembly as in section 16.7
2. Carefully slide the ceramic side walls forward to remove.
3. Carefully slide the ceramic rear wall upward to remove.
4. Replace in the reverse order.

16.11 To remove the electronic ignition generator.

1. Remove the window frame and window assembly as in section 16.7.
2. Remove the ceramic fuel effect as in section 16.9
3. Remove the battery.
4. Remove the spark lead.
5. Unscrew the four support bracket screws (See figure 46). The generator and its
support bracket can now be moved forward. Be careful not to apply tension to the
microswitch leads.
© GDC Group Ltd. 2012
INSTALLER GUIDE
Page 42
Figure 45. Window removal