11.3 Inlet pressure check.

The appliance is pre-set to give the correct heat input at the inlet pressure shown in
section 3 of this manual. No adjustment is
necessary.
1. Check the inlet pressure by fitting a pressure
gauge at the test point. The test point is on the
inlet 'T' connector (See figure 24). Check the
pressure with the appliance alight and set at
maximum output.
2. After checking, turn off the appliance. Remove
the pressure gauge and replace the test point
sealing screw.
3. Test around the sealing screw for gas
soundness with a suitable leak detection fluid.
4. Fit the burner tray trim to the front
flanges of the burner. To do this, locate
the tags on the baffle over the front
flanges of the burner and lower into
position (See figure 25).
5. It is advisable at this stage to remove
the battery to avoid accidental ignition
whilst fitting the ceramic fuel effect.

12. FITTING THE CERAMIC FUEL EFFECT

The installer and owner guide for the ceramic fuel effect is supplied with the ceramic
fuel effect. It is important that the fitting guide for the ceramic fuel effect be placed
inside or attached to this guide and handed to the customer following completion of
the 'Final review' section.
©