7.12.2 Replacing the anti-tipping mechanism with locking spring

CAUTION!
Danger of tipping over if the anti-tipping mechanism is installed using a locking spring on
a chair with a lifter.
· Always install the anti-tipping mechanism using a screw in the first drill hole (long adjustment)
on a chair with a lifter, as described in chapter 7.12.1.
Requirements:
· Bar or Stab Phillips screwdriver
· Press the locking spring (2) together. Only the
bolts in the support tube (3) are visible.
· Pull the anti-tipping mechanism out (1).
· Check the locking spring.
· Replace the locking spring if it is broken or
has insufficient tension.
· Replace the anti-tipping mechanism.
· Insert the (possibly new) locking spring (4)
into the anti-tipping mechanism up to the
second hole.
· Insert the anti-tipping mechanism into the
support tube. To do this, press the locking
spring together slightly.
· Insert the anti-tipping mechanism into the
support tube as far as it will go.
· Make sure that the locking spring latches into
the holes provided for this purpose in the
support tube.