Advertisement

®
®
Invacare
- Bora
/Spectra
· Remove the SL fuse (2) on the bottom fixing
bolt (1) with the screwdriver.
· Pull the fixing bolt (1) out.
· Remove the SL fuse (2) on the top fixing bolt
(1) with the screwdriver.
· Pull the fixing bolt (1) out.
· Pull the adjustment spindle with adjusting
motor out.
· Insert a new adjustment spindle with adjusting
motor.
· Reinsert the fixing bolts and SL fuses. Fix the
SL fuses securely to the fixing bolt with the
hammer.
· Reinsert the adjusting motor plug into the
electronics module.
· Secure the adjusting motor cable to the frame
with cable ties. The cable must be routed so
that it does not rub or get trapped.
· To complete, check all seat tilting functions.
®
XTR Series