JRC JMA-5206 Instruction Manual page 399

Table of Contents

Advertisement

Adjustment of Performance Monitor (NJU-64)
* Execution of this item needs a PM unit (option).
JMA-5206/HS has no PM option.
Procedures
1
Set the radar to Master Radar when the Interswitch is installed.
2
Press VRM1 key to display VRM1 and set the range of VRM1 to 10-18*
NM.
3
The Equipment Setup Menu will appear in accordance with the
instructions of section 8.5.
4
Press [4] key.
The TRX Setting Menu will appear.
5
Press [4] key.
The Code Input Menu will appear.
6
Enter a set value.
Adjust the PM pattern so that its outer edge is
within 10 to 18 NM. The multi-function control
is also available for the entry. After having
enter the value, press ENT.
7
Attach the INFORMATION LABEL
provided with the performance monitor
to an appropriate position on the
display unit.
1. Anntena Height
2. Tune Peak Adjust
3. Tune Indicator Adjust
4. PM Adjustment
5.Manual Tune Adjustment
7. Output Pulse
8.Antenna Location
0. EXIT
8─98
8.6 Setting
TRX Setting
5-10m
0
0
0
2048
0m
0m
8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jma-5206hsJma-5220-9Jma-5210-4Jma-5210-6Jma-5220-7