JRC JMA-5206 Instruction Manual page 299

Table of Contents

Advertisement

(2) Rotating section
(a) Supply Oil Seal
When there is not a grease nipple, the replenishment of grease oil is unnecessary.
Remove the cap on the grease nipple located on the side of the X band radar, and grease with a
grease gun.
Make the oiling every six months. The oil quantity shall be approximately 100 g, which is as much
as the grease comes out of the oil seal. Use the grease of Mobilux 2 of Mobil Oil.
(b) Oiling gears
Apply grease evenly to the tooth surfaces of the main shaft drive gear and the encoder drive gear
with a spreader or brush. Oiling in short intervals is more effective to prevent the gears from wear
and tear and extend their service life, but oil at least every six months.
Use Mobilux2 of Mobile Oil.
(c) Mounting legs
Check the mounting legs and mounting bolts of the scanner unit case for corrosion at intervals and
maintain them to prevent danger. Apply paint to them once a half year because painting is the best
measure against corrosion.
7.2 Maintenance on each Unit
7─6
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jma-5206hsJma-5220-9Jma-5210-4Jma-5210-6Jma-5220-7

Table of Contents