2) Toner Supply Amount
- Method 1 -
Normally (if 0 or 1 is selected with SP30), the toner supply amount is
determined by the difference between the actual TD sensor voltage (V
the target toner sensor voltage (V
relationship between the sensor output and the toner supply motor on time
for each copy.
Toner Supply Level
1
2
3
4
5
6 (Near End Level)
7 (Toner End Level)
- Method 2 -
If 2 or 3 is selected with SP30, a fixed amount of toner is supplied when the
TD sensor voltage becomes higher than the target toner sensor voltage. The
amount of toner can be selected using SP32.
Toner Supply Motor On Time
SP32 Setting
0
1
2
3
4
5
Stays on until the TD sensor
6
voltage becomes lower than the
target voltage.
7
SM
CÓPIA NÃO CONTROLADA
). The following table shows the
TS
TD Sensor Voltage Level [V
< V
≤ V
V
+ S/16
TS
T
TS
≤ V
V
+ S/16 < V
+ S/8
TS
T
TS
≤ V
V
+ S/8 < V
+ S/4
TS
T
TS
≤ V
V
+ S/4 < V
+ S/2
TS
T
TS
≤ V
V
+ S/2 < V
+ 4S/5
TS
T
TS
≥ V
V
+ 4S/5
T
TS
≥ V
V
+ S
T
TS
The toner supply time unit "t" can be changed using SP31.
t = SP31 setting x 0.1 [second] (Default: 4 = 0.4 second)
S: TD Sensor Sensitivity (SP36)
* This value can be changed using SP35.
(seconds)
0.3
0.6
1.2
2.4
3.6
4.8
0 (No toner supply)
2-31
CÓPIA NÃO CONTROLADA
TONER SUPPLY
]
Toner Supply Motor On Time
T
t
2 x t
4 x t
8 x t
16 x t
*10 seconds
*10 seconds
Corresponding image area ratio
(%)
3.5
7
15
30
45
60
0
) and
T
A219