Ricoh A219 Service Manual page 339

Table of Contents

Advertisement

PROGRAM MODE
Mode No.
Light Intensity
Clean the optics, then adjust the exposure lamp
Adjustment †
voltage. The V
automatically when entering this mode.
SP Setting
48
Before performing this mode, clean the optics.
Then open SP33 and return the setting to the
normal value if it has been changed. Then adjust
the light intensity using an OS-A3 Test Chart with
the platen cover placed over it. After adjusting the
light intensity, adjust the ADS Reference Voltage
Adjustment (SP56).
See "Replacement and Adjustment - Copy Quality"
for details on how to do this adjustment.
Fusing
Adjusts the control temperature of the hot roller
Temperature
during copying in 1°C steps.
Adjustment
49
Fusing Ready
Adjusts the ready temperature of the hot roller
Temperature
during the warm-up period in 1°C steps.
Adjustment
Normally, this value should not be changed.
50
Exposure
Displays the current exposure lamp voltage.
Lamp Voltage
For 120 V machines, the actual applied
Display
voltage = displayed value/2
51
The exposure lamp turns on for 10 seconds when
this mode is selected. Do not repeat more than 5
times, to avoid overheating the optics cavity.
A245
CÓPIA NÃO CONTROLADA
Function
and V
corrections are reset
L
L2
Lamp Voltage (V)
120 V (NA) Version
100
50.0
101
50.5
102
51.0
Å
150
75.0
Å
180
90.0
Å
193
96.5
194
97.0 Max
11-32
CÓPIA NÃO CONTROLADA
Settings
120 V Machines
100 ~ 194
Default = 140
230 V Machines
100 ~ 180
230 V (EU) Version
Default = 140
100
101
102
150
180 Max
120 V Machines
180°C ~ 195°C
Default = 190°C
230 V Machines
180°C ~ 200°C
Default = 190°C
120 V Machines
160°C ~ 175°C
Default = 172°C
230 V Machines
165°C ~ 180°C
Default = 177°C
0 ~ 247