Ricoh A219 Service Manual page 371

Table of Contents

Advertisement

Mode No.
73
User Code
Counter
Display
(UP 8)
92
User Code
Counter Clear
(UP 9)
SP 70 (No UP mode)
Function: Enables User Code Mode.
Procedure:
1. Access SP mode 70.
2. Select 1: user code mode (Default is 0: No user code).
3. The machine is then ready to access next mode number.
Note: Cut JP101 on the main board.
Procedure to set the user code:
1. "U2" is displayed in the copy counter. Using the number keys, input the three-
digit user code number (e.g.111,123, 999). Available user codes are; 1 - 999.
Please note that 000 is invalid.
2. Press the Auto Image Density key.
3. "U2" is no longer displayed and the machine becomes ready to copy.
4. If any invalid values are entered or other keys are pressed, "U2" will remain
displayed and copies cannot be made.
5. After the copy job is completed (or one minute after the last key is pressed), the
machine initiates Auto Reset and becomes ready to set the next user code. At
this time, "U2" will be displayed and copies cannot be made.
6. As an alternative, you can set the next user code by pressing the Clear
Mode/Energy Star key and then the Clear/Stop key when the machine is in Copy
Ready condition. The machine will then become ready to accept the next user
code.
B019
CÓPIA NÃO CONTROLADA
Displays the copy counter value for each user number registered.
The user number (1-10) is displayed in the copy counter and the
corresponding total copy counter value is displayed in the 3-digit
indicator (Zoom,%). Using the Zoom key (up:+,down:-), you can
view how many copies each registered user has made.
Access mode number 73 (number 8 for UP mode).
"1" is displayed in the copy counter. At first, only 3 digits are
displayed in the 3-digit indicator (6th, 5th and 4th). After you press
the "Darker" key, the next 3 digits will be displayed (3rd, 2nd and
1st).
To exit, press the Auto Image Density key and turn the main
switch off and on.
Clears the total copy counter values for all registered users.
To clear, enter "1" then press the Auto Image Density key and the
"Darker" key at the same time.
To exit, turn the main switch off and on.
User Code Mode selection:
CÓPIA NÃO CONTROLADA
Function
12-4
Data
0: No
1: Yes
SM

Advertisement

Table of Contents
loading

This manual is also suitable for:

B019A245

Table of Contents