PROGRAM MODE
Mode No.
A3/DLT
Specifies whether the counter is doubled for A3/DLT
Double Count
paper.
If "ON" is selected, the total counter, electrical total
counter (SP88), and the current user code counter
27
count up twice when A3/DLT copy paper is used.
This function is not applicable when using the
by-pass feed table, since the by-pass feed table can
not detect copy paper size.
Auto Sort
In Auto Sort Mode, the sorter is automatically
Select
selected when more than 1 original is set on the DF
table and the entered copy quantity is greater than 1
28
and less than 11.
In Manual mode, sort mode has to be selected at
the operation panel.
The sorter and DF must be installed on the machine.
Fusing
Selects the fusing temperature control mode.
Temperature
After selecting the control mode and turning the
29
Control
main switch off/on, the fusing temperature control
Selection
mode is changed.
Toner Supply
Selects the toner supply system.
Mode Selection
Normally, this value should not be changed.
Setting
30
See SP31/SP32 for the toner supply amount.
Toner Supply
Determines how much toner is supplied in detect
Amount
supply mode.
(TD Sensor
Select the toner supply time from 0.0 s to 5.0 s in
31
Mode)
0.1 s steps.
See "Detailed Descriptions-Toner Supply Control"
for more details.
A245
CÓPIA NÃO CONTROLADA
Function
SP
Toner Supply System
Detect supply mode using
0
the initial TD sensor
setting.
Detect supply mode using
1
the target TD sensor
voltage set with SP53.
Detect supply mode (fixed
2
amount) using the initial
TD sensor setting.
Detect supply mode (fixed
amount) using the target
3
TD sensor voltage set
with SP53.
Fixed supply mode.
4
11-28
CÓPIA NÃO CONTROLADA
0: OFF
1: ON
0: Manual
1: Auto Sort
0: ON/OFF
1: Phase
Default = 0
Note
Default
Use only in abnormal TD
sensor conditions.
0 ~ 50
Default = 4
(0.4 s)
Settings
control
control