Ricoh A219 Service Manual page 231

Table of Contents

Advertisement

COPY QUALITY
Yes
No
Is the exposure lamp light intensity too weak due to deterioration?
No
Yes
Replace the 1st scanner unit.
Is the signal at CN102-3 LOW after the ! key is pressed? (No bias
voltage is applied to the development roller.)
No
Yes
Replace the main board.
Replace the high voltage supply board C/G/B/T/S.
Is the cleaning blade worn?
No
Yes
Replace the cleaning blade.
Are the erase lamp and/or quenching lamp dirty?
No
Yes
Clean the erase lamp and quenching lamp, as required.
If toner scattering occurs, see 'Toner Density Too High'.
If dirty background occurs only in ADS mode, do the following:
If the ADS voltage is not within ± 0.2 volts of the standard voltage (2.5
V), readjust the ADS voltage.
If the signal at CN114-5 stays HIGH, check the harness and sensor,
and replace any defective parts.
If the signal at CN114-6 stays LOW, replace the main board.
A219
CÓPIA NÃO CONTROLADA
7-4
CÓPIA NÃO CONTROLADA
SM

Advertisement

Table of Contents
loading

This manual is also suitable for:

B019A245

Table of Contents