Ricoh A219 Service Manual page 135

Table of Contents

Advertisement

PROGRAM MODES
Mode No.
Toner Supply
Selects the toner supply system.
Mode Selection
Normally, this value should not be changed.
Setting
30
See SP31/SP32 for the toner supply amount.
Toner Supply
Determines how much toner is supplied in detect
Amount
supply mode.
(TD Sensor
Select the toner supply time from 0.0 s to 5.0 s in
31
Mode)
0.1 s steps.
See "Detailed Descriptions-Toner Supply Control"
for more details.
Toner Supply
Determines how much toner is supplied in fixed
Amount
supply mode and in detect supply (fixed amount)
(Fixed Supply
mode.
Mode)
For example, if the user normally makes copies of
A4 originals that are about 7% black, select the 7%
setting for best results.
32
See "Detailed Descriptions - Toner Supply Control"
for more details.
A219
CÓPIA NÃO CONTROLADA
Function
SP
Toner Supply System
Detect supply mode using
0
the initial TD sensor
setting.
Detect supply mode using
1
the target TD sensor
voltage set with SP53.
Detect supply mode (fixed
2
amount) using the initial
TD sensor setting.
Detect supply mode (fixed
amount) using the target
3
TD sensor voltage set
with SP53.
Fixed supply mode.
4
SP
Supply
Ratio
Setting
Time
0
3.5%
1
7.0%
2
15%
3
30%
4
45%
5
60%
6
7
0%
4-14
CÓPIA NÃO CONTROLADA
Note
Default
Use only in abnormal TD
sensor conditions.
Note
0.3 s
Default
0.6 s
1.2 s
2.4 s
3.6 s
4.8 s
Continuous supply
0
No toner supply
Settings
Default = 0
0 ~ 50
Default = 4
(0.4 s)
0 ~ 7
Default = 0
SM

Advertisement

Table of Contents
loading

This manual is also suitable for:

B019A245

Table of Contents